ACI
Send water analysisRequest a quote

Product code: BR2000

Brackish Water RO Antiscalant

Antiscalant for brackish water reverse osmosis, for controlling inorganic scale and metal oxides.

Category
Antiscalants

Request a quoteDownload the datasheet

BR2000 product in an ACI jerrycan

Overview

BR2000 is a reverse osmosis antiscalant specially formulated for brackish water. It is a general antiscalant with a synergetic mixture of organic polymers, adapted to control inorganic scales and metal oxides in brackish water reverse osmosis plants.

The product sheet states that it is effective at a Langelier Saturation Index (LSI) of up to +2.6. It can be diluted with RO permeate or distilled water before it is fed.

The treatment rate and the operating instructions are set for each system by our technical team. For technical data, a treatment recommendation for your system or a product sample, contact our technical team with a recent water analysis and your operating data.

Handling

Keep out of reach of children.

Do not breathe vapour or spray.

Avoid contact with skin and eyes.

In case of contact with skin, flush immediately with plenty of water and seek medical advice.

Storage: keep the container tightly sealed and store in a cool, well-ventilated area below 30 °C, away from direct sunlight.

Key features

  • Compatible with major RO membranes
  • Suitable for RO and NF membranes
  • Can replace acid addition in suitable systems
  • Effective at LSI up to +2.6

Applications

Brackish water reverse osmosis plants.

Reverse osmosis (RO) and nanofiltration (NF) membranes.

Scale types addressed, as listed in the product sheet: calcium carbonate and calcium sulphate, calcium phosphate, iron and manganese.

Technical data

Specifications

Form
Aqueous liquid
Colour
Yellow to orange
pH (concentrate)
below 3
Solubility in water
Completely soluble
Effective up to
LSI +2.6
Packaging
25 kg

Product data sheet

A printable A4 sheet of this product, from the same approved record as this page.

Open the data sheet

Let's discuss your water system.

Share the application and operating context to start a technical review.