Short, direct answers to common questions about RO membranes, cooling water, chilled-water loops and boilers, written for engineers and plant teams.

Illustrative clear water droplet and ripplesIllustration

These answers are short on purpose. Each one addresses a single question that engineers and plant teams ask when they run RO, cooling, chilled-water or boiler systems.

General answers cannot replace a review of your own system. If your question depends on your water or operating conditions, send those details to our technical team.

Questions are grouped by the system they concern, so you can go straight to RO, cooling, chilled-water or boiler topics. Where an answer rests on a product datasheet, it says so.

How often should RO membranes be cleaned?

There is no fixed calendar interval. Clean when normalized performance shows a clear change from the commissioning baseline: a rising differential pressure, falling normalized permeate flow or rising salt passage. Cleaning earlier, while the deposit is still thin, recovers performance more fully than waiting until the loss is severe.

Sources: Guide: when to clean RO membranes

Reviewed by: Owner ·

Why is RO differential pressure increasing?

A rising differential pressure means the feed channels between membrane sheets are being blocked. The usual causes are particulates and colloids, biological growth, or scale from sparingly soluble salts. Where in the train the rise starts, and how fast it moves, helps separate these causes before choosing a cleaner.

Sources: Problem page: RO differential pressure increase · Guide: causes of RO membrane fouling

Reviewed by: Owner ·

What does an RO antiscalant do?

An antiscalant keeps sparingly soluble salts, such as carbonates and sulfates, in solution as the feed water is concentrated along the membrane train. It delays crystal growth and deposition on the membrane surface, so recovery can be run without scale forming in the concentrate stream.

Sources: Solution page: RO chemicals · Problem page: RO membrane scaling

Reviewed by: Owner ·

How can antiscalant use be optimized?

Start from a current feed water analysis and the planned recovery, then set the treatment rate from the analysis and operating conditions rather than from habit. Confirm the choice by watching differential pressure and salt passage, and review it whenever the feed source, recovery or temperature changes.

Sources: Guide: selecting an antiscalant for brackish water RO

Reviewed by: Owner ·

Which cleaner suits scale and which suits biological or organic fouling?

Mineral scale is normally removed with an acidic cleaner, while biological and organic deposits respond to an alkaline cleaner. The right order depends on what the deposit is, so identify the foulant from the performance trend and a cleaning analysis first, and rinse thoroughly between the two steps.

Sources: Guide: causes of RO membrane fouling · Guide: when to clean RO membranes

Reviewed by: Owner ·

What causes biofouling on RO membranes?

Microorganisms in the feed attach to the membrane and spacer surfaces, multiply on the nutrients present and build a slimy biofilm that raises differential pressure and lowers flow. It is usually worse after warm weather, a weak pretreatment barrier or a period of idle stagnation.

Sources: Problem page: RO membrane biofouling

Reviewed by: Owner ·

Why record baseline data when an RO system is commissioned?

Baseline readings of pressures, flows, conductivity and temperature taken at start-up show what clean membranes do on the actual feed water. Later trends are judged against them, so fouling and scaling can be identified early instead of being mistaken for normal seasonal change.

Sources: Service page: installation and commissioning · Guide: when to clean RO membranes

Reviewed by: Owner ·

What does RO maintenance involve?

RO maintenance covers routine performance logging and normalization, cartridge filter and pretreatment checks, chemical feed checks, membrane cleaning when the trend calls for it and a review of operating data.

Sources: Service page: RO maintenance

Reviewed by: Owner ·

How can fouling be told apart from normal changes in RO performance?

Normalize permeate flow, differential pressure and salt passage for feed temperature, pressure and recovery, then compare them with the start-up baseline. Raw readings move with the seasons and load. A steady drift in the normalized values, not a swing in the raw ones, points to fouling or scaling.

Sources: Guide: when to clean RO membranes · Problem page: RO differential pressure increase

Reviewed by: Owner ·

Why does pretreatment matter for an RO system?

Pretreatment removes or controls what would otherwise foul the membranes: suspended solids, oxidants that attack the polymer, dissolved organics and microorganisms. A weak pretreatment stage shows up downstream as faster fouling, more frequent cleaning and a shorter membrane life.

Sources: Guide: causes of RO membrane fouling

Reviewed by: Owner ·

How are RO membranes protected during a long shutdown?

Flush the system with suitable quality water, then keep the membranes wet and preserved with a suitable disinfectant solution so that biological growth cannot establish. Membranes must never be allowed to dry out. Follow the membrane supplier instructions for the preservation solution and for restart.

Sources: Solution page: RO chemicals · Problem page: RO membrane biofouling

Reviewed by: Owner ·

What causes corrosion in cooling towers?

Corrosion follows from dissolved oxygen, low or aggressive pH, high chloride and sulfate content, galvanic contact between different metals, and deposits or biofilm that create under-deposit attack. Concentrating the water by evaporation makes each of these worse unless blowdown and inhibitor treatment keep the chemistry in balance.

Sources: Problem page: cooling tower corrosion · Guide: cooling tower scale versus corrosion

Reviewed by: Owner ·

What causes scale in cooling towers?

Evaporation concentrates dissolved hardness and alkalinity in the recirculating water. Where solubility is exceeded, especially on warm heat-transfer surfaces, calcium carbonate and related salts crystallize and deposit. High cycles of concentration, high pH and high temperature all raise the scaling tendency.

Sources: Problem page: cooling tower scale · Guide: why cooling water conductivity matters

Reviewed by: Owner ·

Why does cooling water conductivity matter?

Conductivity is a quick indicator of how concentrated the circulating water has become, so it is the usual control signal for blowdown. Too high and scale and corrosion risk rise; too low and water and chemicals are wasted. It supports, but does not replace, a full water analysis.

Sources: Guide: why cooling water conductivity matters

Reviewed by: Owner ·

How is biological growth controlled in cooling water?

Control combines a clean, well-drained system, removal of deposits that shelter organisms, and a biocide programme monitored by microbiological testing. Isothiazolinone-based and DBNPA-based biocides are both used in cooling systems, and alternating them is a common way to keep microorganisms from adapting.

Sources: Guide: biological fouling in cooling systems · Problem page: cooling water biological growth

Reviewed by: Owner ·

How can cooling tower scale be told apart from corrosion?

Scale appears as hard, pale, adherent crust on warm surfaces and fill, and shows up as falling heat transfer. Corrosion appears as red-brown or black tuberculation, pitting, metal loss and iron in the water. Inspection of exchanger surfaces plus water and coupon results settle which one dominates.

Sources: Guide: cooling tower scale versus corrosion

Reviewed by: Owner ·

What should be monitored in a cooling tower treatment programme?

Monitor pH, conductivity, the inhibitor residual such as zinc where a zinc-based product is used, corrosion indicators from coupons or probes, and microbiological counts. Together they show whether blowdown, inhibitor and biocide are keeping scale, corrosion and growth under control.

Sources: Solution page: cooling water treatment · Zinc-based cooling tower inhibitor datasheet

Reviewed by: Owner ·

What causes corrosion in closed-loop chilled water systems?

Even a sealed loop corrodes when oxygen enters through make-up water, leaks or open expansion tanks, when the inhibitor residual falls, or when mixed metals and deposits set up galvanic and under-deposit attack. Water that is not monitored drifts out of its protective range unnoticed.

Sources: Problem page: closed-loop corrosion · Guide: closed-loop chilled water treatment

Reviewed by: Owner ·

What is a nitrite-based closed-loop chiller inhibitor?

It is a corrosion inhibitor based on sodium nitrite that forms a thin protective film on steel surfaces in closed chilled-water circuits. Its protection depends on keeping the nitrite residual within the range stated for the product, which is why regular testing of the loop water is part of the programme.

Sources: Closed-loop chiller inhibitor datasheet · Solution page: chilled water treatment

Reviewed by: Owner ·

Why does a sealed chilled-water loop still need treatment?

A closed loop is never perfectly closed: make-up water, small leaks and maintenance openings let in oxygen, minerals and microorganisms. Untreated, the loop corrodes, sheds iron that fouls heat exchangers and may support microbial growth, all of which reduce cooling efficiency and shorten equipment life.

Sources: Guide: closed-loop chilled water treatment · Solution page: chilled water treatment

Reviewed by: Owner ·

How is a closed-loop chiller inhibitor monitored?

Test the loop water for the inhibitor residual, nitrite in the case of a nitrite product, together with pH, conductivity and iron, and compare corrosion coupon results over time. A falling residual or rising iron signals a leak, make-up dilution or active corrosion that needs a response.

Sources: Closed-loop chiller inhibitor datasheet · Guide: closed-loop chilled water treatment

Reviewed by: Owner ·

Can microbial growth occur in closed chilled-water systems?

Yes. Low-flow branches, dead legs and warm sections let bacteria establish biofilm even in a closed loop, and some bacteria accelerate corrosion under the film. Good circulation, clean make-up water and periodic microbiological testing, with biocide treatment where results call for it, keep the loop healthy.

Sources: Guide: biological fouling in cooling systems · Problem page: closed-loop corrosion

Reviewed by: Owner ·

How does make-up water affect a closed chilled-water loop?

Every addition of make-up water dilutes the inhibitor and brings in fresh oxygen, hardness and chlorides. Frequent or unexplained make-up is therefore a warning of leakage, and the inhibitor residual should be re-tested and restored after any significant top-up or draining.

Sources: Guide: closed-loop chilled water treatment · Problem page: closed-loop corrosion

Reviewed by: Owner ·

What causes scale in boilers?

Hardness salts and silica carried in with feedwater lose solubility as the water heats and concentrates, and bake onto hot heat-transfer surfaces. Poor feedwater softening, high concentration without enough blowdown, and metal oxides from corroding condensate lines all add to deposits that insulate the tubes and cause overheating.

Sources: Problem page: boiler scale deposits · Guide: boiler water chemical selection

Reviewed by: Owner ·

What causes oxygen corrosion in boilers and feedwater systems?

Dissolved oxygen in feedwater attacks steel quickly when the water is hot, causing pitting in the feedwater heater, economizer and boiler. Incomplete mechanical deaeration, air leaks into the condensate return and a missing or underfed oxygen scavenger leave the oxygen free to react with the metal.

Sources: Problem page: boiler oxygen corrosion · Guide: oxygen scavengers, DEHA versus sulfite

Reviewed by: Owner ·

How do DEHA-based and sulfite-based oxygen scavengers differ?

Both remove dissolved oxygen from boiler feedwater. Sulfite-based scavengers react quickly but add dissolved solids and are usually limited to lower-pressure boilers. DEHA-based scavengers add no dissolved solids and also help passivate metal surfaces, so the choice follows boiler pressure, water quality and feedwater system design.

Sources: Guide: oxygen scavengers, DEHA versus sulfite · Oxygen scavenger datasheets

Reviewed by: Owner ·

What causes corrosion in steam condensate lines?

Carbon dioxide from decomposing alkalinity dissolves in condensate to form carbonic acid, which lowers pH and eats away the pipe wall, often as grooving. Oxygen entering the return system adds further attack. A neutralizing amine raises condensate pH so the acid is neutralized along the line.

Sources: Problem page: condensate line corrosion · Neutralizing amine datasheet

Reviewed by: Owner ·

Why does boiler feedwater pH matter?

Steel is protected by a stable oxide film only in mildly alkaline water. If feedwater or boiler water pH is too low, the film dissolves and corrosion accelerates; if it is too high, caustic attack and carryover become risks. A pH booster adjusts the water into the protective range.

Sources: Solution page: boiler water treatment · Boiler pH booster datasheet

Reviewed by: Owner ·

Why is boiler water conductivity monitored?

Conductivity tracks the dissolved solids that build up as steam leaves and feedwater replaces it. It guides blowdown: too high invites scale, foaming and carryover into the steam, too low wastes heat and treated water. It is read together with pH and the treatment residuals.

Sources: Guide: boiler water chemical selection · Solution page: boiler water treatment

Reviewed by: Owner ·

Do you provide technical datasheets?

Yes. Our technical datasheets state the category, application, function, product type and packaging. Approved datasheets are published on the product page, and our technical team can send the datasheet that matches your system on request, including for products whose sheet is still being prepared.

Sources: Product datasheets · Products catalogue

Reviewed by: Owner ·

What pack sizes are available?

Every product datasheet lists the same pack sizes in its packaging section, from smaller packs up to an intermediate bulk container (IBC), and the product page shows them under Packaging. Tell our technical team the size you need when you request a quote.

Sources: Product datasheets, packaging section · Products catalogue

Reviewed by: Owner ·

How can I request a product sample?

Product samples are requested from our technical team, as our datasheets state. Use the request form and name the product or the problem you want to test, with your application and water details, so that the sample suits your system.

Sources: Request a quote or sample · Product datasheets

Reviewed by: Owner ·

How is the treatment rate for a product determined?

The rate is set from the water analysis and the operating conditions of the system, then confirmed by monitoring, not read from a fixed table. Pressure, temperature, cycles of concentration and make-up water quality all change what is needed, so the rate is reviewed whenever those conditions change.

Sources: Product datasheets, application notes

Reviewed by: Owner ·

What should I send for a technical review of my system?

Send your operating data and a recent water analysis to our technical team: the system type, feed or make-up water source, key operating conditions, the problem you see and any past treatment. With that, the team can match a product category and monitoring plan to your system.

Sources: Request a quote or consultation

Reviewed by: Owner ·

Which product category suits my system?

Match the category to the system and the problem. RO plants use antiscalants and membrane cleaners. Open cooling towers use scale and corrosion inhibitors with biocides. Closed chilled-water loops use a closed-loop inhibitor. Boilers use oxygen scavengers, pH boosters, scale inhibitors and, for condensate, neutralizing amines.

Sources: Products catalogue · Solution page: boiler water treatment

Reviewed by: Owner ·