ACI
Send water analysisRequest a quote

Applications

Brackish Water RO

Brackish water RO removes dissolved salts from water of moderate salinity. Scaling, fouling and biofouling of the membranes are the main risks, and they show up first as differential pressure and output.

Illustrative reverse-osmosis membrane pressure vessels
On this page (7)

Overview

Reverse osmosis (RO) pushes water through semi-permeable membranes under pressure so that dissolved salts stay behind in a concentrate stream. Brackish water RO treats feed water of moderate salinity from wells, rivers or reuse sources. It is used to prepare boiler make-up, process water and drinking or service water. The salts removed do not disappear: they leave in a smaller volume of concentrate, which is therefore more scale-prone than the feed.

How does a brackish water RO system work?

Feed water passes through pretreatment, typically filtration and cartridge filters, and sometimes dechlorination or chemical conditioning, before a high-pressure pump sends it to the membrane stages. Permeate (the product water) is collected, and concentrate is rejected. Antiscalant is fed ahead of the membranes, and membranes are cleaned when performance falls. Instruments show feed, permeate and concentrate flow, pressure and conductivity.

What are the water-chemistry risks?

  • Scaling: as water is concentrated in the membrane stages, sparingly soluble salts can crystallise on the membrane surface and block it.
  • Particulate and colloidal fouling: suspended matter and iron that pass pretreatment coat the membrane.
  • Biofouling: bacteria form a film on the membrane and spacers, raising differential pressure and reducing output.
  • Organic fouling: dissolved organic matter adsorbs on the membrane surface.
  • Oxidant damage: chlorine or other oxidants that reach the membrane degrade it permanently.

How is brackish water RO monitored?

Monitoring tracks differential pressure across each stage, permeate flow and conductivity, feed pressure and the trend of normalised performance. A rising differential pressure points to fouling or scaling, falling output to scaling or compaction, and rising permeate conductivity to membrane damage or scale. Cartridge filter condition, feed analysis and records of cleaning help to link a symptom to its cause.

Which chemical categories are relevant?

Our RO chemical range includes antiscalants for sea and brackish water, membrane cleaners and a disinfectant. Treatment rates are set by our technical team from the feed water analysis and the system design, and cleaning is planned from the observed symptom, not from the calendar alone.

Considerations

Points to take into account when treating a brackish water RO system. These are qualitative guidance and not a recommendation for a specific plant.

  • A recent, complete feed water analysis, including the ions that drive scaling and any iron, silica or organic content.
  • Pretreatment performance, because everything it misses reaches the membranes.
  • Recovery and stage design, which set how concentrated the reject becomes.
  • Compatibility of antiscalants and cleaners with the membrane material and with each other.
  • Normalising data so that changes in temperature and pressure do not hide real fouling.
  • Preservation of membranes during shutdowns.
  • Chemical handling and cleaning waste disposal.

Our technical team can review a feed water analysis and the operating data before discussing a program.

Related industries

Related solutions

Related products

Related problems

Related questions

How often should RO membranes be cleaned?

There is no fixed calendar interval. Clean when normalized performance shows a clear change from the commissioning baseline: a rising differential pressure, falling normalized permeate flow or rising salt passage. Cleaning earlier, while the deposit is still thin, recovers performance more fully than waiting until the loss is severe.

Sources: Guide: when to clean RO membranes

Reviewed by: Owner ·

Why is RO differential pressure increasing?

A rising differential pressure means the feed channels between membrane sheets are being blocked. The usual causes are particulates and colloids, biological growth, or scale from sparingly soluble salts. Where in the train the rise starts, and how fast it moves, helps separate these causes before choosing a cleaner.

Sources: Problem page: RO differential pressure increase · Guide: causes of RO membrane fouling

Reviewed by: Owner ·

What does an RO antiscalant do?

An antiscalant keeps sparingly soluble salts, such as carbonates and sulfates, in solution as the feed water is concentrated along the membrane train. It delays crystal growth and deposition on the membrane surface, so recovery can be run without scale forming in the concentrate stream.

Sources: Solution page: RO chemicals · Problem page: RO membrane scaling

Reviewed by: Owner ·

How can antiscalant use be optimized?

Start from a current feed water analysis and the planned recovery, then set the treatment rate from the analysis and operating conditions rather than from habit. Confirm the choice by watching differential pressure and salt passage, and review it whenever the feed source, recovery or temperature changes.

Sources: Guide: selecting an antiscalant for brackish water RO

Reviewed by: Owner ·

Which cleaner suits scale and which suits biological or organic fouling?

Mineral scale is normally removed with an acidic cleaner, while biological and organic deposits respond to an alkaline cleaner. The right order depends on what the deposit is, so identify the foulant from the performance trend and a cleaning analysis first, and rinse thoroughly between the two steps.

Sources: Guide: causes of RO membrane fouling · Guide: when to clean RO membranes

Reviewed by: Owner ·

What causes biofouling on RO membranes?

Microorganisms in the feed attach to the membrane and spacer surfaces, multiply on the nutrients present and build a slimy biofilm that raises differential pressure and lowers flow. It is usually worse after warm weather, a weak pretreatment barrier or a period of idle stagnation.

Sources: Problem page: RO membrane biofouling

Reviewed by: Owner ·

Why record baseline data when an RO system is commissioned?

Baseline readings of pressures, flows, conductivity and temperature taken at start-up show what clean membranes do on the actual feed water. Later trends are judged against them, so fouling and scaling can be identified early instead of being mistaken for normal seasonal change.

Sources: Service page: installation and commissioning · Guide: when to clean RO membranes

Reviewed by: Owner ·

What does RO maintenance involve?

RO maintenance covers routine performance logging and normalization, cartridge filter and pretreatment checks, chemical feed checks, membrane cleaning when the trend calls for it and a review of operating data.

Sources: Service page: RO maintenance

Reviewed by: Owner ·

How can fouling be told apart from normal changes in RO performance?

Normalize permeate flow, differential pressure and salt passage for feed temperature, pressure and recovery, then compare them with the start-up baseline. Raw readings move with the seasons and load. A steady drift in the normalized values, not a swing in the raw ones, points to fouling or scaling.

Sources: Guide: when to clean RO membranes · Problem page: RO differential pressure increase

Reviewed by: Owner ·

Why does pretreatment matter for an RO system?

Pretreatment removes or controls what would otherwise foul the membranes: suspended solids, oxidants that attack the polymer, dissolved organics and microorganisms. A weak pretreatment stage shows up downstream as faster fouling, more frequent cleaning and a shorter membrane life.

Sources: Guide: causes of RO membrane fouling

Reviewed by: Owner ·

How are RO membranes protected during a long shutdown?

Flush the system with suitable quality water, then keep the membranes wet and preserved with a suitable disinfectant solution so that biological growth cannot establish. Membranes must never be allowed to dry out. Follow the membrane supplier instructions for the preservation solution and for restart.

Sources: Solution page: RO chemicals · Problem page: RO membrane biofouling

Reviewed by: Owner ·

Which product category suits my system?

Match the category to the system and the problem. RO plants use antiscalants and membrane cleaners. Open cooling towers use scale and corrosion inhibitors with biocides. Closed chilled-water loops use a closed-loop inhibitor. Boilers use oxygen scavengers, pH boosters, scale inhibitors and, for condensate, neutralizing amines.

Sources: Products catalogue · Solution page: boiler water treatment

Reviewed by: Owner ·

Let's discuss your water system.

Share the application and operating context to start a technical review.