Applications
Steam Boilers
Steam boilers concentrate dissolved solids as they raise steam. Scale and corrosion inside the boiler are the main risks, and they are managed through water chemistry, blowdown and monitoring.

On this page (7)
Overview
A steam boiler heats feedwater until it turns to steam, which leaves the boiler and carries heat to the plant. The dissolved solids in the feedwater stay behind in the boiler water and become more concentrated as steam is raised. Blowdown removes some of this concentrated water, and fresh feedwater replaces what was lost as steam and as blowdown.
How does a steam boiler system work?
Treated make-up water and returned condensate are mixed and usually deaerated before the feed pump sends them to the boiler. Inside the boiler, heat from the fire side passes through metal surfaces into the water. Steam leaves through the steam header, and some water is removed by blowdown to control concentration. Each stage affects the next, so the quality of the feedwater determines the condition of the boiler internals.
What are the water-chemistry risks?
- Scale and deposits: hardness, silica and iron that reach the boiler can form insulating deposits on hot surfaces, which reduce heat transfer, raise metal temperature and may lead to overheating.
- Oxygen corrosion: dissolved oxygen in the feedwater pits boiler metal and feed lines, especially during idle periods.
- Alkalinity and pH: water that is too acidic attacks metal, while an unsuitable alkaline balance can promote carryover or deposits.
- Carryover: foam and entrained water can reach the steam and damage downstream equipment.
- Metal transport: iron and copper from corroded condensate lines settle in the boiler and add to deposits.
How is a steam boiler monitored?
Monitoring covers the pH of the boiler water, conductivity or total dissolved solids to control blowdown, hardness of the feedwater, residual of the oxygen scavenger and indicators of corrosion such as iron in samples. Inspection of the boiler internals at shutdown shows what the chemistry has actually done. Records of blowdown and make-up help to spot a change early.
Which chemical categories are relevant?
Our datasheets describe a boiler pH booster, a boiler scale and corrosion inhibitor, a multipurpose boiler product and a neutralizing amine for steam and condensate, alongside the oxygen scavengers used in feedwater. Treatment rates are set by our technical team from the water analysis and the operating conditions, fed with a chemical metering pump.
Considerations
Points to take into account when treating a steam boiler. These are qualitative guidance and not a recommendation for a specific boiler.
- Boiler type and operating pressure class, which affect the feedwater purity the boiler needs.
- Feedwater quality and the performance of softening, RO or deaeration ahead of the boiler.
- Condensate return share and its condition, since returned iron and copper end up in the boiler.
- Where steam contacts product or people, which limits which chemicals may be considered.
- Load pattern, because frequent start-up and shutdown increases idle-period corrosion risk.
- Blowdown practice and heat recovery, which affect both cost and chemistry.
- Lay-up during long shutdowns, which needs its own plan.
Our technical team reviews the water analysis and boiler details before any program is proposed.
Related industries
Manufacturing
Water systems typical of manufacturing plants, the operating problems that follow when the chemistry drifts, and how a problem-led approach keeps production loops stable.
Food and Beverage
Steam, chilled water, RO-treated process water and effluent shape food and beverage operations. This page outlines the typical systems, problems and decision points.
Power and Utilities
Boilers, condensate systems, cooling towers and RO make-up treatment are central to power and utilities plants. This page outlines the typical systems and problems.
Hospitality
Hotels and resorts depend on chilled water, cooling towers, steam and treated water for comfort and service. This page outlines their typical systems and the problems that follow.
Oil and Gas
Cooling water, steam, desalination and produced or process effluent are central utilities in oil and gas facilities. This page outlines typical systems and problems.
Industrial Contractors
Industrial contractors build and maintain plants, RO packages, boilers and cooling systems for operators. This page outlines the typical concerns on the water side.
Related solutions
Boiler Water Treatment for Low and Medium Pressure Boilers
Oxygen control in feedwater, pH control in the boiler, internal scale and corrosion inhibition, and neutralizing amines to protect condensate lines.
Water Analysis Request
How to send a water analysis, the system type, the capacity and the current problem to our technical team so your case can be reviewed.
Related products

Boiler water chemicals
BO 1300 Boiler pH Booster
Boiler water treatment that helps maintain the boiler water pH and supports corrosion control in industrial and commercial boilers.

Boiler water chemicals
BO 1500 Boiler Scale and Corrosion Inhibitor
Treatment that helps control scale formation and corrosion in industrial and commercial boiler systems.

Boiler water chemicals
BO 1500 MP Neutralizing Amine for Steam and Condensate Systems
Neutralizing amine treatment that helps control acidic condensate corrosion in steam and condensate return systems.

Boiler water chemicals
BO 1400 NA Steam and Boiler Treatment
Treatment for steam and boiler systems, as named on the product label.
Related problems
What causes scale and deposits in boilers?
Boiler scale forms when hardness, silica and iron deposit on heated surfaces. Learn the effects, causes, the checks to run and the scale and corrosion inhibitor approach.
How does dissolved oxygen corrode boilers and how do you stop it?
Dissolved oxygen in boiler feedwater causes pitting of feed lines, economisers and boiler surfaces. Learn the signs, checks and the oxygen scavenger approach.
Related questions
What causes scale in boilers?
Hardness salts and silica carried in with feedwater lose solubility as the water heats and concentrates, and bake onto hot heat-transfer surfaces. Poor feedwater softening, high concentration without enough blowdown, and metal oxides from corroding condensate lines all add to deposits that insulate the tubes and cause overheating.
What causes oxygen corrosion in boilers and feedwater systems?
Dissolved oxygen in feedwater attacks steel quickly when the water is hot, causing pitting in the feedwater heater, economizer and boiler. Incomplete mechanical deaeration, air leaks into the condensate return and a missing or underfed oxygen scavenger leave the oxygen free to react with the metal.
How do DEHA-based and sulfite-based oxygen scavengers differ?
Both remove dissolved oxygen from boiler feedwater. Sulfite-based scavengers react quickly but add dissolved solids and are usually limited to lower-pressure boilers. DEHA-based scavengers add no dissolved solids and also help passivate metal surfaces, so the choice follows boiler pressure, water quality and feedwater system design.
What causes corrosion in steam condensate lines?
Carbon dioxide from decomposing alkalinity dissolves in condensate to form carbonic acid, which lowers pH and eats away the pipe wall, often as grooving. Oxygen entering the return system adds further attack. A neutralizing amine raises condensate pH so the acid is neutralized along the line.
Why does boiler feedwater pH matter?
Steel is protected by a stable oxide film only in mildly alkaline water. If feedwater or boiler water pH is too low, the film dissolves and corrosion accelerates; if it is too high, caustic attack and carryover become risks. A pH booster adjusts the water into the protective range.
Why is boiler water conductivity monitored?
Conductivity tracks the dissolved solids that build up as steam leaves and feedwater replaces it. It guides blowdown: too high invites scale, foaming and carryover into the steam, too low wastes heat and treated water. It is read together with pH and the treatment residuals.
Which product category suits my system?
Match the category to the system and the problem. RO plants use antiscalants and membrane cleaners. Open cooling towers use scale and corrosion inhibitors with biocides. Closed chilled-water loops use a closed-loop inhibitor. Boilers use oxygen scavengers, pH boosters, scale inhibitors and, for condensate, neutralizing amines.
Let's discuss your water system.
Share the application and operating context to start a technical review.